A Comparative Analysis of Three Single-Phase GCPV-Based DSTATCOM System Using Conjugate Gradient Backpropagation and Frequency Domain Control Algorithms

Authors

  • Aini Syahida Mohd Shaizad Department of Electrical Engineering, Faculty of Electrical Engineering & Technology, University of Malaysia Perlis, 02600 Arau, Perlis, Malaysia
  • Nor Hanisah Baharudin Department of Electrical Engineering, Faculty of Electrical Engineering & Technology, University of Malaysia Perlis, 02600 Arau, Perlis, Malaysia
  • Tunku Muhammad Nizar Tunku Mansur Department of Electrical Engineering, Faculty of Electrical Engineering & Technology, University of Malaysia Perlis, 02600 Arau, Perlis, Malaysia
  • Rosnazri Ali Centre of Excellence for Renewable Energy (CERE), Faculty of Electrical Engineering & Technology, Universiti Malaysia Perlis, Pauh Putra Campus, 02600 Arau, Perlis, Malaysia
  • Mohd Syahril Noor Shah Centre of Excellence for Renewable Energy (CERE), Faculty of Electrical Engineering & Technology, Universiti Malaysia Perlis, Pauh Putra Campus, 02600 Arau, Perlis, Malaysia
  • Norjasmi Abdul Rahman Centre of Excellence for Renewable Energy (CERE), Faculty of Electrical Engineering & Technology, Universiti Malaysia Perlis, Pauh Putra Campus, 02600 Arau, Perlis, Malaysia

Keywords:

DSTATCOM, FFT, Power quality, Harmonic

Abstract

Power quality is important for distribution system as it may impact both the provider and consumer of the electricity negatively if it has an issue such as harmonic current. This issue may result in a breakdown of equipment of both the consumer and the provider hence why it important to solve the power quality issue. Therefore, this research is conducted to overcome the power quality issues that is faced by the distribution system by adding DSTATCOM to the system as it can compensate harmonic current. Fast Fourier Transform (FFT) is chosen as DSTATCOM controller for this research. The outcome for this project is that the THD value of the source current need to be below 8% as stated in IEEE standard 519-2014. All the simulations are performed by using MATLAB/Simulink where it has been proved that the THD of source current has been greatly reduced after adding DSTATCOM compensation to it.

Downloads

Download data is not yet available.

Downloads

Published

2025-10-02

How to Cite

Mohd Shaizad, A. S. ., Baharudin, N. H. ., Tunku Mansur, T. M. N. ., Ali, R. ., Noor Shah, M. S. ., & Abdul Rahman, N. . (2025). A Comparative Analysis of Three Single-Phase GCPV-Based DSTATCOM System Using Conjugate Gradient Backpropagation and Frequency Domain Control Algorithms. Journal of Advanced Research Design, 144(1), 214–225. Retrieved from https://akademiabaru.com/submit/index.php/ard/article/view/6779
سرور مجازی ایران Decentralized Exchange

Issue

Section

Articles

Most read articles by the same author(s)

فروشگاه اینترنتی