Parametric Study and Multi-Objective Optimization of Vapor Compression Heat Pump System by Using Environmental Friendly Refrigerant

Authors

  • Nyayu Aisyah Department of Mechanical Engineering, Faculty of Engineering, Universitas Indonesia, Depok, Indonesia
  • M Idrus Alhamid Department of Mechanical Engineering, Faculty of Engineering, Universitas Indonesia, Depok, Indonesia
  • Nasruddin Nasruddin Department of Mechanical Engineering, Faculty of Engineering, Universitas Indonesia, Depok, Indonesia
  • Sholahuddin Sholahuddin Faculty of Science andEngineering, Waseda University, Shinjuku-ku, Tokyo 169-8555, Japan
  • Arnas Lubis Faculty of Science andEngineering, Waseda University, Shinjuku-ku, Tokyo 169-8555, Japan
  • Kiyoshi Saito Faculty of Science andEngineering, Waseda University, Shinjuku-ku, Tokyo 169-8555, Japan

Keywords:

environmental friendly refrigerant, heat pump, multi-objective optimizatio, parameter study

Abstract

This study proposes the parameter study and multi-objective optimization of a vapor compression heat pump system using environmentally friendly refrigerant, R1224yd(Z). The effect of three design parameters including refrigerant mass flow rate, evaporation temperature, and condensation temperature on compressor work, cooling load in the evaporator, heat rejected by the condenser, and exergy of the system are investigated through parameter studies. A multi-objective optimization was then performed. Exergy efficiency and exergoenvironmental value are the objectives of this optimization scenario. The purpose of the optimization is to obtain the optimum value of three design parameters in terms of exergy and environmental point of views so that the heat pump system has maximum exergy efficiency and minimum effect to the environment. The result showed that the system will be in the optimum condition at Te = 287.98 K, Tc= 315.56 K and refrigerant mass flow rate = 0.0321 kg/s with the exergy efficiency of 38.48% and exergoenvironmental value of 200.98 mPts/h.

Downloads

Published

2020-12-14

How to Cite

Aisyah, N. ., Alhamid, M. I. ., Nasruddin, N., Sholahuddin, S., Lubis, A. ., & Saito, K. . (2020). Parametric Study and Multi-Objective Optimization of Vapor Compression Heat Pump System by Using Environmental Friendly Refrigerant. Journal of Advanced Research in Fluid Mechanics and Thermal Sciences, 54(1), 44–56. Retrieved from https://akademiabaru.com/submit/index.php/arfmts/article/view/2434