Analysis of Optimum Thickness of Glass Wool Roof Thermal Insulation Performance

Authors

  • Mohammed W. Muhieldeen Department of Mechanical Engineering, Faculty of Engineering, Technology & Built Environment, UCSI University, Kuala Lumpur, Malaysia
  • Lim Zhen Yang Department of Mechanical Engineering, Faculty of Engineering, Technology & Built Environment, UCSI University, Kuala Lumpur, Malaysia
  • Lim Chong Lye School of Engineering and Technology, PSB Academy, Singapore
  • Nor Mariah Adam Department of Basic Science and Engineering, Universiti Putra Malaysia, Bintulu Campus, Sarawak, Malaysia

Keywords:

Optimum insulation, Energy savings, Tropical climate, Glass wool insulation

Abstract

Countries in south east Asia are mostly experiencing tropical climate conditions. Therefore, the use of the air conditioning has been increased to reduce the tension and achieve thermal comfort inside the buildings. In order to reduce the energy consumption, thermal insulation has been introduced to lower down the indoor temperature. The main objective of this study is to determine the optimum thickness of the glass wool insulation. To conduct the study, a wooden room model is built based on the classroom that located at one of the Malaysian universities. The thicknesses of the glass wool insulation used in the experiment is 25 mm (one layer), 50 mm (two layers) and 75 mm (three layers). According to the results, the maximum temperature reduction for one layer of insulation is 1.0°C. Two layers of insulation reduces the indoor temperature by 1.3°C followed by the reduction of 1.5°C after applying three layers of insulation. The convection coefficient outside and inside is determined to calculate the heat flux of the roof with different insulation thickness. The heat flux gained by the roof reaches the highest value at 1 pm which is 0.648 W/m² without insulation. The heat flux has been reduced to 0.629 W/m² after applying one layer of glass wool insulation. The heat flux gained by the roof is further reduced to 0.573 W/m² and 0.518 W/m² when two and three layers of insulation are applied, respectively. Throughout the experiment, the temperature inside the room is reduced with the increase of the insulation thickness. Two layers of glass wool insulation has been selected as the optimum insulation thickness which is validated after performing calculation using the polynomial function as well as the cost analysis. Two layers of glass wool insulation yields a 27.40% of ROI per annum.

Published

2021-07-20
فروشگاه اینترنتی